PERIODIC MAINTENANCE
JH Series Operation Manual 61
12/05
Note: These procedures are considered normal maintenance and are performed at the owner’s expense.
Cooling
System
Seawater outlet
During
Operation
Check coolant level
Check or replace the
seawater pump impeller

Replace coolant Every year. When Long Life Coolant is used, replace every 2 years.
See Engine Coolant Specifications on page 41.
Clean and check the
seawater passages
●
Air Intake
and
Exhaust
System
Clean intake silencer (air
cleaner) element
Clean or replace the
exhaust/water mixing elbow

Wash the turbocharger
blower - 4JH80/4JH110 only
●
Check diaphragm assembly
4JH45/4JH57 only
●
Electrical
System
Check the alarm and
indicators
Check the electrolyte level in
the battery
Adjust the tension of the
alternator V-ribbed belt or
replace V-ribbed belt
Initial 50

Check the wiring connectors
Engine
Cylinder
Head and
Block
Check for leakage of fuel,
engine oil and engine coolant
After
starting
Tighten all major nuts and
bolts
●
Adjust intake/exhaust valve
clearance
● Initial 50 ●
Miscellane
ous Items
Check the remote control
cable operation
Initial 50 ●
Adjust the propeller shaft
alignment
●Initial 50 ●
Replace rubberized hoses
(fuel and water)
Replace every 2 years.
: Check or Clean : Replace ●: Consult your authorized Yanmar Marine dealer or distributor
System Item Periodic Maintenance Interval
Daily
See Daily
Checks
on
page 62.
Every 50
hours or
monthly
which- ever
comes first
Every 250
hours or 1
year which-
ever comes
first
Every 500
hours or 2
years
which- ever
comes first
Every 1000
hours or 4
years
which- ever
comes first