6. Periodic Inspections and Maintenance
25
EN
6.2.1.7 By using Yanmar Hand
Pump
First follow steps (3) and (4) on page 24.
(1) Connect the hoses as shown above
at the top adapter joint to the hand
pump by using the rubber hose.
(2) Take out the plug from the upper
case cover.
(3) Fill in the oil moved by the hand
pump. Be aware that oil has to flow
down through narrow parts and
then up again. Therefore, during
this procedure, at first suction
pressure will be high and pumping
will be hard. A few minutes waiting
in between will help. The hand
pump (p/#: 28210-000080) and rub-
ber hose (p/#: 196440-92970) are
available from Yanmar, and are op-
tional parts for SD50/-4T. Or any
type of hand pump or rubber hose
(Inner diameter ø14-16 mm) avail-
able from the hardware shop, are
usable.
(4) After filling, first screw in and tight-
en the plug at the top cover. Then
remove the hand pump, hose and
adapter joint and screw in the oil
plug (don't forget the gasket).
6.2.1.8 By not using pump
For the oil filling procedure by not using
pump, see the explanation on chapter 4.,
page 10.
APlug
A
003456-00E